Click to enlarge image
|
|
SMX-16
2.5Gbps Fiber Optic SDH Transmission System
-.Transmission
Capacity : STM-16
-.Tributary signal : 48xDS3 or 16xSTM1,4xSTM-4
-.Configuration : Point-To-Point, Ring-ADM, Linear ADM
|
1.
Overview
The SMX-16
is a high capacity SDH Multiplexer which can multiplex standard PDH
and SDH bit rates up to 2.5 Gbit/s(STM-16) also have various application
mode(TERM, REG, Linear ADM , UPSR and BLSR-2F). Because of this wide
range in capacity this system is useful element in building efficient
and flexible network and used in regional and backbone network. The
SMX-16 transmits at STM-16(2.5Gbps) bit rate and tributary signals
are STM-4(622Mbps), STM-1(155Mbps) and DS-3(45Mbps). The SMX-16 can
accept ATM level signal(AU-4-Xc) and has full cross connect capability(48x48
VC3). For easy maintance, the SMX-16 has GUI terminal and TMN Q interface.
2.
Features
-. Compact design
-. Mixed Hierarchy interface ( AU-3 and AU-4 )
-. ATM mode interface (AU-4-Xc)
-. Full Cross Connect Capability( 48 x 48 VC-3 level )
-. Flexibility in application and protection capabilities
-. ESGUI(Eastel Systems Graphic User Interface) LAN Interface
-. ESNMS(Eastel Systems Network Management System) by DCC channel
-. Q3 interface in TMN( Telecommunication Management Network )
3.
System Applications
4.
Specifications
|
Capacity
|
-
max 48 X DS3 or 16 X STM-1 or 4 X STM-4 or mixed signal |
|
Specification
|
General
ITU Recommendations : G.707, G.708, G.709
Equipment Recommendations : G.781, G.782, G.783, G.784,
G.813
Physical Interfaces : G.957, G.703
Performance requirements : G.823, G.825, G.826 |
| Mapping
Structure |
AU-4-xC,
AU3 |
| Timing
and Synchronization |
-
2 External 2M input
- STM-16 inputs
- STM-1,4 inputs
- Internal Oscillator Strutum-3 accuracy 4.6ppm
G.813 Option 1, stability 0.37ppm first 24 hours |
Transmission
Performance
|
Jitter
on STM-N interfaces : G.813/G.825
Jitter on PDH interface : G.823/G.783
Error Performance : G.826
Performance monitoring : G.784/G.826 |
| Pretection
and Redundancy |
Tributary
level redundancy
- 1+1 nonrevertive bi/uni MSP in STM-N level
- 1+1 nonrevertive circuit/unit protection in DS-3 level
SNCP protection on VC3 , VC4 level
MS-SPRing
Maximum of 50msec switching time for all protection mechanism |
|
|